Customization
Built Around Your Site – Not Around Ours
Fully shielded modular enclosure with verified Faraday-grade protection, EMP-rated SPDs, and concurrent-maintainable power/cooling for sensitive workloads.
Book a 30-min call

Why Customization Matters
- Traditional data‑center models force you to adapt your project to someone else’s template. ModulEdge reverses that logic.
- Each module is a bespoke engineering object – designed to your grid capacity, climate, and regulatory envelope.
Benefits at a glance
Predictable uptime, because design starts from site constraints.
Verified environmental and mechanical fit before fabrication..
Use Lower total cost of deployment by removing civil‑works waste.case
Core Areas You Can Specify
Structure and Layout
- ISO or custom footprints (6 m – 14 m) with optional vestibule or operator zone.
- Dedicated Power, IT, Cooling, or Meet‑Me Room modules — or an All‑in‑One build.
- Anti‑vibration mounting for mobile or seismic sites.
Power Systems
- Redundancy levels N / N+1 / 2N, designed to meet Tier III/IV
- principles.
- Dual utility or generator feeds with ATS.
- UPS scope selectable: IT‑only, shared, or cooling‑dedicated.
- AC, DC, or hybrid distribution; autonomy defined at intake.
Cooling Systems
- Air, in‑row, or hybrid topologies.
- Free‑cooling packages for mild climates; economizer integration.
- Zoned thermal management up to 150 kW/rack.
- Continuous cooling loops for high‑availability environments.
Environmental
- Dust, sand, and humidity sealing per ISO 14644 / IEC 60529.
- Tested for −40 °C to +55 °C ambient conditions.
- Optional EMP/EMI shielding aligned with MIL‑STD‑188‑125‑1.
- FK‑5‑1‑12 or inert gas fire suppression; multi‑zone detection.
Validation and Monitoring
— In-Factory Testing
Each customized system is built and tested in‑factory before shipping.
— Site Verification (SAT)
Site Acceptance Test verifies operation after commissioni
— Factory Validation
Factory Acceptance Test covers electrical load, cooling balance, and safety integration.
— Monitoring & Control
Standarts: Modbus, SNMP, BACnet, REST API — ready for any DCIM/BMS environment.
Designed for Engineers, Proven in action
- Integrated CAD / CFD design validation.
- Optional Uptime design‑review support.
- Full MEP drawing set and FAT/SAT documentation.
- CE and IEC compliant.
Outcome: a field‑ready system that matches your specification, not just your budget.
Customization Workflow
Design Intake
Power envelope, redundancy, and climate data.
Engineering Review
Mechanical, electrical, and control schematics.
Design Approval
3D layout + BoM sign‑off.
Factory Build & FAT
4–6 months from design lock.
Delivery & SAT
Transport, commissioning, and training.
Let’s Build Together
Ready to start your design review?
Ready to discuss your project? Our engineers will tailor the setup to your exact environment and power needs.
FAQ
What power densities do you support?
From 5 kW per rack for standard IT loads up to 150 kW per rack for GPU-intensive AI workloads. We design the power distribution, cooling, and thermal management as an integrated system matched to your specific density requirements.
What cooling options are available?
DX cooling for standard densities (5 to 15 kW/rack), chilled water and adiabatic systems for mid-range (15 to 40 kW/rack), and direct-to-chip liquid cooling for high-density GPU configurations (up to 100+ kW/rack). We also offer hybrid and free-cooling options depending on your climate and energy costs.
What Tier levels do your data centers support?
We design and build to Tier I through Tier IV principles. The tier level depends on your redundancy and availability requirements. Our engineering team is Uptime Institute certified, so we design to the standard from day one and can support formal certification audits if your project requires it.
Do you offer EMP shielding?
Yes. We offer Faraday-grade EMP/IEMI shielding as an option for defense, government, and critical infrastructure applications. This is integrated into the container structure during manufacturing.
Will this integrate with our existing monitoring and access control?
Yes. Every module comes with integrated monitoring and access/CCTV systems. During the design review, we align these with your existing tools, security protocols, and network management platforms.
What container sizes are available?
Standard 20-ft and 40-ft ISO containers. We can configure from 4 racks in a 20-ft unit up to 16+ racks in a 40-ft unit. Custom form factors are possible for specific site constraints.
What's included in factory acceptance testing?
Full FAT/SAT documentation. Every module is powered on, thermally tested, and validated in our facility before shipment. You get detailed test reports covering power distribution, cooling performance, fire suppression, monitoring, and access control systems.